tag-stop
tag-stop attaches to a tag, sends the stop command, and prints the status read
back after the command completes.
Usage
tag-stop [options]
Options
| Option | Value | Function |
|---|---|---|
-d, --debug |
none | Enables debug logging. |
-b, --base |
BUS:DEVICE |
Selects a specific USB device by bus and device address. |
-h, --help |
none | Prints command usage and exits. |
Preconditions
- A compatible tag/base interface is connected over USB.
- Use
--base BUS:DEVICEwhen more than one compatible interface is connected. - Download any needed logs before stopping if the active run should continue.
Examples
tag-stop
tag-stop --base 20:7
Output
The command prints the protobuf Status message returned after the stop command.
On a successfully stopped active tag, the state is typically ABORTED.
Troubleshooting
No matching device: no connected tag/base matched the optional--baseselector.Attach failed: the USB interface was found but could not be opened.Stop failed: the monitor did not acknowledge the stop command.Could not read tag status: the command was sent, but the follow-up status request failed.