qtcalibrate

qtcalibrate is the host application for collecting live magnetometer samples, fitting magnetometer calibration constants, saving/loading those constants on a tag, and previewing the resulting compass orientation.

Source Layout

Path Purpose
mainwindow.* and mainwindow.ui Qt Widgets application shell: tag attach/detach, calibration controls, log window, menus, timers, and the embedded QML orientation views.
compassdata.* The live calibration on Qt types: an adapter over calibcore::CalibrationSession (sensoranalysis/core/calibration_session.h), which owns the sample buffer, Freescale's magcal solver, retention, the accelerometer fit, the quality figures and the filtered live compass. The Rust Tag Calibrator uses the same session.
magplot.* Interactive 2D widget that draws calibrated magnetometer samples as a rotatable sphere projection during calibration.
sinbin.* Small trigonometric lookup/helper code used by the inherited calibration routines.
Magnetic Calibration.pdf Reference notes for the calibration approach.

The app no longer owns local compass/attitude QML. Runtime orientation display comes from host/libraries/sensorui:

  • CompassDisplay wraps orientation_frame/MyCompass.qml.
  • AttitudeDisplay wraps orientation_frame/MyAttitude.qml.

The app calls initializeSensorUiResources() before loading the shared qrc:/qfi/... QML URLs.

Runtime Flow

  1. MainWindow::Attach() finds a base, attaches to a tag, and reads tag config and status.
  2. The stream checkbox starts periodic TriggerUpdate() polling.
  3. Each streamed calibration sample may contain magnetometer and accelerometer readings.
  4. If calibration is active, magnetometer samples go through CompassData::addData(), which updates the inherited magcal solver and then refreshes magPlot.
  5. While calibration is active, MainWindow also keeps an in-memory sample capture of the raw calibration-window magnetometer stream and any paired accelerometer values.
  6. If orientation can be computed, CompassData::eCompass() applies the current calibration, low-pass filters the live vectors, and uses CompassProcessor for the shared eCompass quaternion solve.
  7. MainWindow sends the resulting Euler values to CompassDisplay and the display quaternion to AttitudeDisplay.

Sample Capture

Pressing Start begins an in-memory calibration sample capture. Pressing Stop, disabling streaming, or detaching finalizes the capture. The File > Save Sample Capture action is enabled after a stopped capture has at least one magnetometer sample.

The archive is a JSON file with schema tag-designs.qtcalibrate.calibration-capture.v1. It records the received magnetometer samples, any paired accelerometer samples, capture start/stop times, and the fitted calibration constants and quality metrics when the solver has produced a valid calibration.

Sample Replay

Every command below is run from the build output directory, where the binary lands -- <build-dir>/<config>/bin -- hence ./qtcalibrate. A fixture path written relative to the repository root still resolves from there: resolveReplayCapturePath() tries the path as given, then the same path under the source tree, whose location is compiled in. Output paths such as --log-file are not resolved that way and land in the current directory.

For documentation and fixture review, qtcalibrate can load a saved sample capture instead of attaching to a USB tag:

./qtcalibrate --replay-capture host/docs/fixtures/qtcalibrate/qtcalibrate-samples-20261010-145438.json

The replay path presents the window as a fake attached tag. Enabling Stream replays captured samples through the same calibration UI path used by live samples, so Start and Stop also exercise sample capture.

Use --replay-percent to prefill the Calibrate tab for static screenshots:

./qtcalibrate --replay-capture host/docs/fixtures/qtcalibrate/qtcalibrate-samples-20261010-145438.json --replay-percent 25

Supported milestone values are ordinary percentages from 0 to 100. A 0 percent milestone starts collection without feeding samples. A 100 percent milestone feeds the full fixture and finalizes the capture.

To generate the baseline Calibrate-tab documentation screenshots and exit:

./qtcalibrate --capture-startup-screenshot

./qtcalibrate \
  --replay-capture host/docs/fixtures/qtcalibrate/qtcalibrate-samples-20261010-145438.json \
  --capture-replay-screenshots

./qtcalibrate \
  --replay-capture host/docs/fixtures/qtcalibrate/qtcalibrate-samples-20261010-145438.json \
  --capture-orientation-screenshot

By default this writes qtcalibrate-startup.png, qtcalibrate-collection-000.png, qtcalibrate-collection-025.png, qtcalibrate-collection-050.png, qtcalibrate-collection-100.png, and qtcalibrate-orientation-forward.png and qtcalibrate-orientation-backward.png into host/docs/src/images/. Use --screenshot-dir or --screenshot-prefix to override the replay milestone defaults.

Orientation screenshots use a fixed documentation pose by default. Override it with --orientation-pose heading,pitch,roll,dip,field,gravity when a different heading or attitude is clearer.

Sample Retention

Once the calibration buffer is full every new sample displaces an old one, and which one is discarded decides what the solver ever sees.

MagRetention discards the sample of lowest leverage -- the one contributing least to determining the fit -- or, ahead of that, one whose studentized residual says the reading itself is wrong, with a patch floor and a probation window as guards. It declines when there are too few samples or the design is one the data cannot determine, and the caller then takes a slot at random: that is exactly when discarding on leverage would be guesswork.

This replaced an inherited nearest-pair scan, which was selected by a --leverage-retention flag while the two were compared and is gone along with magcal/quality.c, whose gap figure it branched on. The comparison is in the investigation.

A replay is reproducible, which is what let that comparison mean anything:

./qtcalibrate --replay-capture <capture.json> --replay-exit --log-file run.txt

--replay-exit starts the sweep, runs it to the end of the capture and quits, and --log-file writes the DEBUG lines the log window would show. Without them a run ends wherever Save Log is clicked, and two runs of one capture differ by more than most of the things worth measuring.

log_set_quiet(true) means the DEBUG lines never reach stdout or stderr, so --log-file is the only way to capture them without the window.

A run logs a retention: line with the eviction count and how many each rule decided, a gravity: line with the fitted accelerometer offset, and the magquality: metrics.

Calibration Constants

Calibration constants move between three representations:

  • the solver state (MagCalibration_t) inside the calibration session,
  • protobuf CalibrationConstants on the tag: MagConstants (hard-iron V, soft-iron A) and AccelConstants (zero-g offset, mg),
  • UI labels in the calibration tab.

CompassData::getCalibrationConstants() and CompassData::setCalibrationConstants() are the boundary between MainWindow and inherited solver state. Save writes the magnetometer constants and the accelerometer offset together; without an accelerometer fit the offset is written as zero. The tag does not store the field magnitude B, so Load recomputes it from any buffered samples. A loaded accelerometer offset is installed with CompassData::setAccelOffset() and stands until a live fit replaces it.

The orientation view has a top-level Configuration menu and matching context menu entries for declination and battery-forward display convention. Those are display settings only; they do not change stored calibration constants.

The menu bar is in the window, as in sensorviz and qtmonitor. Help (Tag Calibrator User Guide, About) is added by HostUserGuide::addHelpMenu() from host/common/qtuserguide.h, after the Configuration menu so it is last.

The log level combo in the log pane selects what reaches the log window; it opens at INFO.

Streaming pitch/roll/yaw samples are logged at TRACE through log_trace() so normal log levels do not flood the log window: there is one such line per streamed sample.

The calibration quality metrics from sensoranalysis's MagQuality are logged at DEBUG, once per quality timer tick, as a line beginning magquality:. They are deliberately a level above the per-sample flood so they can be read without it. They are logged rather than displayed because they are computed alongside the inherited four metrics while the two are compared; see the replacement proposal.